When the inverter drives the motor, leakage faults often occur. What are the causes of inverter leakage? How to prevent and solve it?


1 Main reason

1). Equipment aging or damage: The inverter used for a long time may be aged or damaged, resulting in reduced insulation performance and leakage.

2). Use environment problems: If there is too much dust or foreign matter in the working environment of the inverter, the cable may be broken and poorly contacted, causing leakage.

3). Power line problems: Poor contact, aging, and high cable temperature of the power line can cause leakage in the inverter.

4). Electrical failure: When encountering short circuit, overload, overvoltage and other faults, leakage may also occur.


2. Prevention and resolution

1). Equipment maintenance: Regularly inspect and maintain the inverter equipment, replace aging parts in time, and clean up dust and foreign objects, which can effectively reduce the possibility of leakage.

2). Check the power line: Ensure that the power line is connected correctly and firmly, check for aging and damage problems, and reduce the risk of leakage.

3). Replace the inverter: When the inverter is aged or faulty and it is inconvenient to repair, replace the equipment in time to ensure operating performance and safety.


The frequency converter is a device used to adjust the voltage and frequency of AC power. It is widely used in industrial production and can effectively control the running speed of the motor and save energy. However, the frequency converter may have leakage problems during use, which will not only affect the normal operation of the equipment, but also pose a threat to the safety of the staff. In order to avoid the harm caused by the leakage problem of the frequency converter, we need to take some measures to solve and prevent this problem.


First of all, we can find potential leakage problems by regularly inspecting and maintaining the frequency converter. When inspecting, pay attention to observe whether the appearance of the frequency converter is damaged and leakage signs, check whether the cable connection is good, whether the cable is worn, etc. In addition, the frequency converter should be regularly tested for leakage current to check whether it exceeds the safety standard, and adjust and repair the problem in time.


Secondly, we can also install a leakage protection device to prevent the frequency converter leakage problem. The leakage protection device can monitor the leakage in the frequency converter circuit. Once leakage is detected, the power supply can be cut off immediately to prevent the damage and harm caused by leakage. When selecting a leakage protection device, you should choose the appropriate type and specification according to different environments and needs to ensure that it can effectively monitor and control the inverter leakage problem.


In general, the inverter leakage problem is a common hidden danger, which requires us to pay attention to and take corresponding preventive measures. Through regular inspection and maintenance, installation of leakage protection devices and other methods, the inverter leakage problem can be effectively solved and prevented, ensuring the safe operation of the equipment and the personal safety of the staff. I hope the above content is helpful to you.